Electromagnetic Flow Meter Partially Filled Pipe

Size: DN200-DN3000
Connection: Flange
Liner Material: Neoprene/Polyurethane
Electrode Marerial: SS316, Ti, Ta, HB, HC
Structure Type: Remote Type

Product Details

Introduction
Partially filled pipe electromagnetic flow meter is a kind of volume flow meter. It was specially designed for partially filled pipe. It can measure liquid volume from 10% level of the pipe to 100% level of the pipe. It’s accuracy can reach to 2.5%, very accurate for irrigation and waste water liquid measurement. It use remote LCD display so users can read the flow measurement easily. We also provide solar power supply solution for some remote areas where has no power supply.
Advantages

Partially filled pipe electromagnetic flow meter Advantages & Disadvantages

Partially filled pipe electromagnetic flow meter can measure partially filled pipe liquid flow, it is very popular in irrigation.
Its can use solar power supply, this type is very suitable for remote areas where has no industrial power supply.
It adopts safe and durable material, service life is longer than normal products. Normally, it can work at least 5-10 years or longer.
And we have already got food grade certificate for its liner so it can be used for drinking water, underground water, etc. Many drinking water company use this type in their big size pipeline.
We use an accurate mini ultrasonic level meter for its liquid level measurement then the flow meter will record the liquid level and use this parameter to measure liquid flow. This ultrasonic level meter’s blind area is very small and its accuracy can reach to ±1mm.

Application

Partially filled pipe electromagnetic flow meter can measure water, waste water, paper pulp, etc. We use rubber or polyurethane liner on it, so it can measure most of none corrosive liquid. It is mainly used in irrigation, water treatment, etc.
It withstand -20-60 deg C media temperature, and it was very durable and safe.
Technical Data

Table 1: Partially Filled Pipe Electromagnetic Flow Meter Parameters

Measuring Pipe Size DN200-DN3000
Connection Flange
Liner Material Neoprene/Polyurethane
Electrode Marerial SS316, TI, TA, HB, HC
Structure Type Remote Type
Accuracy 2.5%
Output Signal Modbus RTU, TTL electrical level
Communication RS232/RS485
Flow speed range 0.05-10m/s
Protection Class Converter: IP65

Flow Sensor: IP65(standard), IP68(optional)

 Table 2: Partially Filled Pipe Electromagnetic Flow Meter Size

Drawing ( DIN Flange )
Diameter

(mm)

Nominal

pressure

L(mm) H φA  φK N-φh
DN200 0.6 400 494 320 280 8-φ18
DN250 0.6 450 561 375 335 12-φ18
DN300 0.6 500 623 440 395 12-φ22
DN350 0.6 550 671 490 445 12-φ22
DN400 0.6 600 708 540 495 16-φ22
DN450 0.6 600 778 595 550 16-φ22
DN500 0.6 600 828 645 600 20-φ22
DN600 0.6 600 934 755 705 20-φ22
DN700 0.6 700 1041 860 810 24-φ26
DN800 0.6 800 1149 975 920 24-φ30
DN900 0.6 900 1249 1075 1020 24-φ30
DN1000 0.6 1000 1359 1175 1120 28-φ30

Table 3: Partially Filled Pipe Electromagnetic Flow Meter Model Select

QTLD/F X X X X X X X X X
Caliber size DN80-DN3000(3″-120″)
Structure Remote 1
Remote with explosion proof 2

Lining Material

Neoprene 1
FEP 2
PFA 3
PTFE 4
Polyurethane 5
Hard Rubber 6
Others 7

Electrode Material

SS316L 1
Hastelloy B 2
Hastelloy C 3
Titanium 4
Tantalum 5
Platinum-iridium 6
Stainless steel covered with tungsten carbide 7
Others 8
Sensor Material Carbon Steel 1
SS304 2
SS316 3
Power Supply 20~36 VDC G
85~265 VAC E
9~36 VDC solar power SD
Others X
Signal Output
/Communication
4~20 mA + Pulse + RS485 MODBUS A
4~20 mA + HART B
4~20 mA + Profibus C
GPRS D

Flange Standard

DIN     D6:DIN PN6, D10: DIN PN10, D16: DIN PN16 D**
ANSI  A15: ANSI 150# A**
JIS     J10: JIS 10K, J20: JIS 20K, J30: JIS 30K J**
Others O
Protection Grade IP65 Transmitter + IP65 sensor 1
IP65 Transmitter + IP68 sensor 2

Installation

Partially Filled Pipe Electromagnetic Flow Meter Installation and Maintainance

1.Installation
Partially filled electromagnetic flow meter should be installed correctly to ensure good measurement. Normally we need leave 10D(10 times of diameter) straight pipe distance before partially filled pipe electromagnetic flow meter and 5D behind partially filled pipe electromagnetic flow meter. And try to avoid elbow/valve/pump or other device which will influent the flow speed. If the distance is not enough, then please install flow meter according to follow picture.

lnstall at the lowest point and vertical upward direction
Don’t install at the highest point or vertical downward diection

When drop is more than 5m, install exhaust
valve at the downstream

lnstall at the lowest point when used in open drain pipe

Need 10D of upstream and 5D of downstream

Dont’ install it at the entrance of pump, install it at the exit of pump

lnstall at the rising direction

2.Maintenance
Routine maintenance: only need to make periodic visual inspections of the instrument, check the environment around the instrument, remove dust and dirt, ensure that no water and other substances enter, check whether the wiring is in good condition, and check whether there are newly installed strong electromagnetic field equipment or newly installed wires near the instrument Cross-instrument. If the measuring medium easily contaminates the electrode or deposits in the measuring tube wall, it should be cleaned and cleaned regularly.
3.Fault finding: if the meter is found to work abnormally after the flow meter has been put into operation or normal operation for a period of time, the external conditions of the flow meter should be checked first, such as whether the power supply is good, whether the pipeline is leaking or in a state of partial pipe, whether there is any in the pipeline Whether air bubbles, signal cables are damaged, and whether the output signal of the converter (that is, the input circuit of the subsequent instrument) is open. Remember to dismantle and repair the flow meter blindly.
4.Sensor inspection
5.Converter check

TANCO

Please contact us if you have any technical questions about the product.

Submit your specifications for a comprehensive quotation and feasibility study.